  obsolescence notice this product is obsolete. this information is available for your convenience only. for more information on zarlink?s obsolete products and replacement product lists, please visit http://products.zarlink.com/obsolete_products/
2-7 features ? 2 x high power, high voltage, thick ?lm surge protection resistors ? 2 x high accuracy, high stability matched battery feed resistors ? 2 replaceable 2ag fuses in surface-mounted fuse clips ? used with the mh89626c for a complete ops line interface applications ? battery feed and secondary protection for off- premise slics description the MH80626C hybrid sip provides a protection circuit consisting of two 2ag size fuses in surface- mounted fuse clips and two high voltage, high power 5.5 w surge resistors. the MH80626C also provides two high stability, high power 50 w feed resistor matched to 0.1%. the sip provides full secondary protection for the mh89626c off-premise slic, allowing conformance to the requirements of various international safety and performance standards. figure 1 - functional block diagram f1 f2 r1 r2 tin rin r3 r4 r5 tcom tf t rf2 rf1 r rf rcom issue 2 april 1995 ordering information MH80626C 20 pin sil package 0 c to 70 c MH80626C battery feed/protection sip preliminary information
2-8 MH80626C preliminary information figure 2 - pin connections pin description pin # name description 1 tin tip input. connects to tip conductor of the subscriber loop. 2nc no connection: there is no pin in this location 3ic internal connection : do no connect to this pin. 4nc no connection: there is no pin in this location. 5 tcom tip common: connects to tip pin of the slic via a normally closed ringing relay. see figure 1. 6t tip connection: connects to tip pin of the slic. 7r ring connection: connect to the ring pin of the slic. 8 rcom ring common: connects to ring pin of the slic via a normally closed ringing relay. see figure 1. 9nc no connection: there is no pin in this location. 10 ic internal connection: do not connect to this pin . 11 nc no connection: there is no pin in this location. 12 rf ring feed connection: connects to the rf pin of the slic. 13 nc no connection: there is no pin in this location. 14 tf tip feed connection: connect to the tf pin of the slic. 15 nc no connection: there is no pin in this location. 16 rf1 ring feed 1. ringing input: connects to ringing supply. 17 nc no connection: there is no pin in this location. 18 rf2 ring feed 2. ringing output: connects to ring line through the ring relay contact. 19 nc no connection: there is no pin in this location. 20 rin ring input: connects to ring conductor of the subscriber loop. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 tin nc ic nc tcom t r rcom nc ic nc rf nc tf nc rf1 nc rf2 nc rin
2-9 preliminary information MH80626C electrical characteristics 0?c to 70?c * typical ?gures are at 25?c and are for design aid only note 1: refer to the appropriate telecom equipment safety speci?cations for full details of the test and requirements characteristics symbol min typ* max units test conditions 1 resistance - absolute r1 4.5 5.5 6 w 2 resistance - absolute r2 4.5 5.5 6 w 3 resistance - match 1 % match between r1 & r2 4 resistance - absolute r3 49.75 50 50.25 w 5 resistance - absolute r4 49.75 50 50.25 w 6 resistance - match 0.1 % match between r3 & r4 7 resistance - absolute r5 555 560 565 w 8 fuse f1 0.25 amps 250 vac slow blow 9 fuse f2 0.25 amps 250 vac slow blow reference speci?cation test description performance comments 1 ccitt k.20 lightning surge simulation 1kv 10 x 700 m sec no damage no arching, fuse intact see note 1 2 ccitt k.20 power induction 300 vrms 200 msec no damage no arching, fuse intact see note 1 3 ccitt k.20 power cross 220 vrms 15 min no damage no arching, fuse blows see note 1
2-10 MH80626C preliminary information figure 3 - mechanical data 2.0 ?? + 0.020 (50.8 + 0.5) 0.7 + 0.020 (17.8 + 0.5) 0.05 + 0.01 (1.3 + 0.5) *** 0.05 + 0.02 (1.225 + 0.05) 0.020 + 0.005 (0.51 + 0.13) 0.100 + 0.010 (2.54 + 0.26) 0.18 + 0.02 (4.6 + 0.5) fuse area fuse area 1 23 4 5 6 0.34 max 0.01 min (0.25) 1 20 notes: 1) not to scale 2) dimensions in inches). 3) (dimensions in millimetres). *dimensions to centre of pin & tolerance non accumulative.
www.zarlink.com information relating to products and services furnished herein by zarlink semiconductor inc. or its subsidiaries (collectively ?zarlink?) is believed to be reliable. however, zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from t he application or use of any such information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or use. neither the supply of such information or purchase of product or service conveys any license, either express or implied, u nder patents or other intellectual property rights owned by zarlink or licensed from third parties by zarlink, whatsoever. purchasers of products are also hereby notified that the use of product in certain ways or in combination with zarlink, or non-zarlink furnished goods or services may infringe patents or other intellect ual property rights owned by zarlink. this publication is issued to provide information only and (unless agreed by zarlink in writing) may not be used, applied or re produced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. the products, t heir specifications, services and other information appearing in this publication are subject to change by zarlink without notice. no warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. it is the user?s responsibility t o fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not b een superseded. manufacturing does not necessarily include testing of all functions or parameters. these products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. all products and materials are sold and services provided subject to zarlink?s conditi ons of sale which are available on request. purchase of zarlink?s i 2 c components conveys a licence under the philips i 2 c patent rights to use these components in and i 2 c system, provided that the system conforms to the i 2 c standard specification as defined by philips. zarlink, zl and the zarlink semiconductor logo are trademarks of zarlink semiconductor inc. copyright zarlink semiconductor inc. all rights reserved. technical documentation - not for resale for more information about all zarlink products visit our web site at


▲Up To Search▲   

 
Price & Availability of MH80626C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X